Furman 15A Advanced Remote Smart Sequencer W/SMP & EVS, 9 Outlets 10Ft Cord(CN-1800S)

Part No:
CN-1800S
Ships from: California
$464.95
List Price: $799.95
  
You save 42%
10 In stock
Is This The Right Item For Me?
800.466.0449
CN-1800S - Overview Furman SmartSequencing technology allows large and complex A/V systems to be safely powered on and off with a simple press of a button or turn of a key - even by non-technical personnel. SmartSequencing's bidirectional communications between installed units enables a primary unit to control and sequence multiple secondary units, ensuring multi-zone electronic systems are powered on and off safely and dependably across an entire installation. Units can be connected via current loop at runs of more than 1,000 feet with full backwards compatibility with Furman's legacy sequencers or a wide variety of third party products. Providing robust control options, the CN-1800S (15 amp) supports RS-232 communication with command sets for integration with control systems. An optional RS-232-to-Ethernet adaptor (sold separately) adds full IP-addressability to the unit, allowing it to be controlled, programmed, and monitored from a smartphone, tablet, PC, or any Web-enabled device via Telnet, direct HTTP connection, or Panamax/Furman's BlueBOLT-hosted remote power and energy management platform. Features: SmartSequencing Technology allows large or complex A/V systems to be safely powered on and off with the simple press of a button or key turn. Series Multi-Stage Protection (SMP) ensures zero downtime for mission critical installations by safely eliminating dangerous surges & spikes. Extreme Voltage Shutdown (EVS) safeguards from catastrophic under and over voltage conditions. Linear Filtering Technology (LiFT) ensures maximum equipment performance by reducing AC noise in a linear fashion across a wide-bandwidth spectrum. 15 amp capacity. Specifications: AC Voltage Input Range: 90-139VAC, 50/60Hz Maximum AC Current Rating: 15 amps (Thermal breaker) AC Cord: 3/14AWG, 10 feet, black, fixed, NEMA 5-15P plug AC Receptacles Rear Panel Outlets: 2 Unswitched NEMA 5 15R's (1 duplex), 6 Sequenced NEMA 5-15R's (3 duplexes each controlled by separate relay) Front Panel: One NEMA 5-15R Convenience Outlet, Unswitched Surge/Under-Overvoltage Protection AC Surge Protection: SMP Spike Protection Mode: Line to neutral, zero ground leakage Spike Clamping Voltage: 188VAC peak @ 6,000 volts/3,000 amps Response Time: 1 nanosecond Maximum Surge Current: 6,500 Amps AC Undervoltage Protection: EVS, 77VAC+/-3VAC AC Overvoltage Protection: EVS, 145VAC+/-5VAC AC Overvoltage Reset Modes: Manual and Auto-reset (configurable) AC Filtering LiFT Noise Attenuation: Linear, 10dB @10KHz, 40dB@100KHz, 50dB@500KHz Operating Temperature Range 5C (40F) to 40C (105F) degrees Humidity Range: <90% rH (Relative Humidity) User Interface Key-switch: Front panel, 3-position key-switch (On, Off, Remote) Keys: Included, 1 pair Push-button Switch: Front panel, hidden by security cover Circuit Breaker: Front panel, push-button, 15A Thermal Breaker Front panel diagnostic indicators: Primary link, Secondary link, Ethernet, Remote off, Delay 1, Delay 2, Delay 3, Power, Protection OK, Extreme Voltage Front Panel DIP Switches: Front panel. Hidden by security cover, 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off BND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual Potentiometer: Front panel, hidden by security cover, fine tune delay adjust Control/Status/Triggering (Rear Panel): Remote Terminal: +5-30VDC In, 12VDC (12mA) Out SmartSequencing: Phoenix 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop - 1000' nominal) Remote Terminal: Phoenix 4-Pin Connector With Screw Terminals; +12V, STAT, REM, GND (Class 2 Wiring) Force Off/Delay 3 Terminal: Phoenix 5-Pin Connector With Screw Terminals, FORCE OFF, DELAY 3 (Class 2 Wiring) RS-232 Compatible: Yes, DB-9 Connector IP Addressability: Optional, via BB-RS232 Ethernet/RS-232 Adapter (sold separately) for IP control via Telnet, HTTP, BlueBOLTr Voltmeter: Available with RS-232/Ethernet option, ± 2VAC accuracy Ammeter: Available with RS-232/Ethernet option, ±1A accuracy Power Consumption (No Load): 10 Watts Safety Agency: NRTL-C, RoHS Compliant GTIN:0654061028451
More Information
Brand Furman Pro
Manufacturer Furman
SKU CN-1800S
UPC 654061028451
Part No CN-1800S
Item Height 4.2
Item Length 21.8
Item Width 15.2
Weight (lb.) 12.6
Carton Quantity 1
Description CN-1800S - Overview Furman SmartSequencing technology allows large and complex A/V systems to be safely powered on and off with a simple press of a button or turn of a key - even by non-technical personnel. SmartSequencing's bidirectional communications between installed units enables a primary unit to control and sequence multiple secondary units, ensuring multi-zone electronic systems are powered on and off safely and dependably across an entire installation. Units can be connected via current loop at runs of more than 1,000 feet with full backwards compatibility with Furman's legacy sequencers or a wide variety of third party products. Providing robust control options, the CN-1800S (15 amp) supports RS-232 communication with command sets for integration with control systems. An optional RS-232-to-Ethernet adaptor (sold separately) adds full IP-addressability to the unit, allowing it to be controlled, programmed, and monitored from a smartphone, tablet, PC, or any Web-enabled device via Telnet, direct HTTP connection, or Panamax/Furman's BlueBOLT-hosted remote power and energy management platform. Features: SmartSequencing Technology allows large or complex A/V systems to be safely powered on and off with the simple press of a button or key turn. Series Multi-Stage Protection (SMP) ensures zero downtime for mission critical installations by safely eliminating dangerous surges & spikes. Extreme Voltage Shutdown (EVS) safeguards from catastrophic under and over voltage conditions. Linear Filtering Technology (LiFT) ensures maximum equipment performance by reducing AC noise in a linear fashion across a wide-bandwidth spectrum. 15 amp capacity. Specifications: AC Voltage Input Range: 90-139VAC, 50/60Hz Maximum AC Current Rating: 15 amps (Thermal breaker) AC Cord: 3/14AWG, 10 feet, black, fixed, NEMA 5-15P plug AC Receptacles Rear Panel Outlets: 2 Unswitched NEMA 5 15R's (1 duplex), 6 Sequenced NEMA 5-15R's (3 duplexes each controlled by separate relay) Front Panel: One NEMA 5-15R Convenience Outlet, Unswitched Surge/Under-Overvoltage Protection AC Surge Protection: SMP Spike Protection Mode: Line to neutral, zero ground leakage Spike Clamping Voltage: 188VAC peak @ 6,000 volts/3,000 amps Response Time: 1 nanosecond Maximum Surge Current: 6,500 Amps AC Undervoltage Protection: EVS, 77VAC+/-3VAC AC Overvoltage Protection: EVS, 145VAC+/-5VAC AC Overvoltage Reset Modes: Manual and Auto-reset (configurable) AC Filtering LiFT Noise Attenuation: Linear, 10dB @10KHz, 40dB@100KHz, 50dB@500KHz Operating Temperature Range 5C (40F) to 40C (105F) degrees Humidity Range: <90% rH (Relative Humidity) User Interface Key-switch: Front panel, 3-position key-switch (On, Off, Remote) Keys: Included, 1 pair Push-button Switch: Front panel, hidden by security cover Circuit Breaker: Front panel, push-button, 15A Thermal Breaker Front panel diagnostic indicators: Primary link, Secondary link, Ethernet, Remote off, Delay 1, Delay 2, Delay 3, Power, Protection OK, Extreme Voltage Front Panel DIP Switches: Front panel. Hidden by security cover, 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off BND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual Potentiometer: Front panel, hidden by security cover, fine tune delay adjust Control/Status/Triggering (Rear Panel): Remote Terminal: +5-30VDC In, 12VDC (12mA) Out SmartSequencing: Phoenix 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop - 1000' nominal) Remote Terminal: Phoenix 4-Pin Connector With Screw Terminals; +12V, STAT, REM, GND (Class 2 Wiring) Force Off/Delay 3 Terminal: Phoenix 5-Pin Connector With Screw Terminals, FORCE OFF, DELAY 3 (Class 2 Wiring) RS-232 Compatible: Yes, DB-9 Connector IP Addressability: Optional, via BB-RS232 Ethernet/RS-232 Adapter (sold separately) for IP control via Telnet, HTTP, BlueBOLTr Voltmeter: Available with RS-232/Ethernet option, ± 2VAC accuracy Ammeter: Available with RS-232/Ethernet option, ±1A accuracy Power Consumption (No Load): 10 Watts Safety Agency: NRTL-C, RoHS Compliant GTIN:0654061028451

Zack Electronics Large Quantity Quote Request

The Zack Electronics Quick Quote system will notify us of your interest in purchasing a large quantity of this item:

Write Your Own Review
How do you rate this product?

Write your own Review