RDL ST-LCR3 Logic Controlled Relay - Dual Alternate Pulse

Part No:
ST-LCR3
Unit of Measure: EACH
Ships from: Arizona
$176.82
List Price: $235.75
  
You save 25%
29 In stock
Is This The Right Item For Me?
800.466.0449
Inputs (2):Logic High or Logic Low (Low = ground, High = 3.3 Vdc to 24 Vdc)
Outputs (2):Open collector @ 25 mA suitable to drive indicators or slave LCRs.
Switching Contacts
Maximum Switching Power:60 W (220 Vdc, 125 Vac, 2 A)
Power Requirement:GROUND-REFERENCED, 24 to 33 Vdc @ 100 mA (assuming 20 mA max load at SLAVE output)
Ambient Operating Environment:0° C to 55° C
More Information
Brand Radio Design Labs
Manufacturer Radio Design Labs
SKU ST-LCR3
UPC 813721012272
Part No ST-LCR3
Weight (lb.) 0.5
Product Datasheet st-lcr3.pdf
Unit EACH
Carton Quantity 1
Short Description

The ST-LCR3 is ideally suited to applications where momentary pulses are needed from a single control signal. The module provides a momentary pulse when a logic signal at its input first becomes active. A separate momentary pulse is provided when the logic signal at the module input becomes inactive.

Two logic inputs are available on the ST-LCR3. Either of these inputs may be used. Terminal 1 is internally pulled high to +5 Vdc. This input becomes active when an external closure or open-collector pulls the terminal to ground. The external switching device does not need to pull the terminal high, however the terminal may be pulled high with any voltage from +3.3 Vdc to +24 Vdc without any risk of damage to the ST-LCR3 input. Terminal 3 is internally pulled to ground. This input becomes active when an external closure or logic device applies a positive voltage from +3.3 Vdc to + 24 Vdc.

When the input being used first becomes active the START PULSE output from the module is triggered. When the input first becomes inactive (after first being active) the END PULSE output from the module is triggered. Both the start and end pulses have a nominal duration of 250 ms.

Each pulse output provides both an open-collector SLAVE terminal and relay contacts. The SLAVE terminal may be used to control other RDL modules and a variety of other equipment. The relay contacts may be used to control modules or equipment that do not operate from open-collector control.

Description
Inputs (2):Logic High or Logic Low (Low = ground, High = 3.3 Vdc to 24 Vdc)
Outputs (2):Open collector @ 25 mA suitable to drive indicators or slave LCRs.
Switching Contacts
Maximum Switching Power:60 W (220 Vdc, 125 Vac, 2 A)
Power Requirement:GROUND-REFERENCED, 24 to 33 Vdc @ 100 mA (assuming 20 mA max load at SLAVE output)
Ambient Operating Environment:0° C to 55° C